Skip to main content
. 2021 Aug 7;27(29):4802–4817. doi: 10.3748/wjg.v27.i29.4802

Table 5.

Autofluorescence endoscopy

Ref.
Study design
Algorithm type
Dataset
Results
Arita et al[44] Diagnostic model development Calculation of a color-contrast index (CCI) for AFI 43 patients who underwent both WL and AF endoscopy Sensitivity: 95.3%
Specificity: 63.6%
Aihara et al[45] Diagnostic model development CAD-assisted AF 32 patients undergoing colonoscopy in a Japanese hospital Sensitivity: 94.2%
Specificity: 88.9%
PPV: 95.6%
NPV: 85.2%
Inomata et al[46] Diagnostic model development CAD-assisted AF 88 patients Accuracy: 82.8%
Sensitivity: 83.9%
Specificity: 82.6%
PPV: 53.1%
NPV: 95.6%
Horiuchi et al[47] Diagnostic model development CAD-assisted AF 95 patients undergoing colonoscopy Accuracy: 91.5%
Sensitivity: 80.0%
Specificity: 95.3%
PPV: 85.2%
NPV: 93.4%

AFI: Autofluorescence imaging; WL: White light; CAD: Computer-aided diagnosis; AF: Autofluorescence.