Table 1:

Distinguishing abnormal perfusion states of the core and penumbra using perfusion imaging.

PERFUSION PARAMETER CORE* PENUMBRA
MTT or Tmax
CBF ↓↓
CBV ↓↓ Normal/↑
*

Core infarct can also demonstrate so-called “luxury perfusion” in which infarcted tissue has normal perfusion imaging appearance.