Skip to main content
. 2021 Aug 18;7(34):eabi8215. doi: 10.1126/sciadv.abi8215

Table 2. Backbone amide (1DNH) RDC analysis of apo and holo Alkbh5.

Used RDCs No. of RDCs DaNH (Hz)* η* Rfac (%)
Back-calculation of RDC data from x-ray structure
  Apo—All RDC 184 8.5 0.30 47.9
  Apo—Best fit 121 15.6 0.50 20.1
  Zn2+/αKG—All RDC 185 10.4 0.32 47.7
  Zn2+/αKG—Best fit 121 15.5 0.51 19.8
  Zn2+/αKG/m6A—All RDC 110 14.0 0.63 48.0
  Zn2+/αKG/m6A—Best fit 76 21.2 0.39 21.4
Ensemble refinement
  Apo—All RDC l 192 25.8
  Zn2+/αKG—All RDC 193 25.1
  Zn2+/αKG/m6A—All RDC 116 25.6

*DaNH and η are the magnitude and rhombicity of the alignment tensor, respectively.

†The RDC Rfac is given by [(DobsDcalc)2/(2Dobs2)]1/2, where Dobs and Dcalc are the observed and calculated RDCs, respectively (57, 58).