Skip to main content
. 2021 Jul 19;59(8):e00319-21. doi: 10.1128/JCM.00319-21

TABLE 1.

Sensitivity and specificity data of the six ELISAs included in the studya

Assay Sensitivity (95% CI) Specificity (95% CI)
Mikrogen IgA 31.6% (21.0–44.5%) 94.0% (83.8–97.9%)
Mikrogen IgG 79.0% (66.7–87.5%) 94.0% (83.8–97.9%)
Euroimmun IgA 91.2% (81.1–96.2%) 86.0% (73.8–93.1%)
Euroimmun IgG 91.2% (81.1–96.2%) 96.0% (86.5–98.9%)
Serion IgA 82.5% (70.6–90.2%) 100.0% (92.9–100.0%)
Serion IgG 98.3% (90.7–99.7%) 100.0% (92.9–100.0%)
a

Sensitivity data were collected on 57 samples positive in the neutralization assay. Specificity data were collected on 50 negative sera. Confidence intervals were calculated using the Wilson score method without continuity correction (25) using a confidence interval calculator sheet (26). Mikrogen, Mikrogen recomWell SARS-CoV-2 IgA/IgG (Mikrogen, Neuried, Germany); Euroimmun, Euroimmun SARS-COV-2 IgA/IgG (Euroimmun, Lübeck, Germany); Serion, Serion ELISA agile SARS-CoV-2 IgA/IgG (Institut Virion/Serion, Wuerzburg, Germany); 95% CI, 95% confidence interval.