Skip to main content
. 2021 Aug 18;62(10):18. doi: 10.1167/iovs.62.10.18

Table 1.

Comparison of Previous Unbiased Proteomic Studies of AH and Vitreous in AMD (The Full List of the Proteins Presented in Supplementary Table S3)

Study Rinsky et al. (2021) Kim et al. (2012) Koss et al. (2016) Siwy et al. (2014)
Source of Sample Aqueous Aqueous Vitreous Vitreous
Mass spectrometry analysis
 AMD patients 10 3 72 73
 Controls 10 3 16 15
 Total proteins identified 674 154 101 97
Proteins upregulated in AMD 239 52 4 (up or down) 19
 Proteins upregulated in control 86 22
Overlap with Rinsky et al. N/A
Validation set and potential biomarkers *
 AMD patients 30** 6 36 4
 Controls 20 5 8 4
 Number of proteins tested 9 7 4 5
AMD Proteins Overlaping 6 discovered in this study 10 new proteins compared to previous studies 40 8
**

aAMD and nvAMD.