Skip to main content
. 2021 Aug 10;7(8):e07752. doi: 10.1016/j.heliyon.2021.e07752

Table 2.

Summary of stability results of Pan and Ami in human plasma using the proposed LC- MS/MS method.

Stability Term QC sample Pan
Ami
QC Conc (μgmL−1) Mean recovered Conc (μgmL−1) % Nominal ±SD CV% QC Conc (μgmL−1) Mean recoverd Conc (μgmL−1) % Nominal ±SD CV%
Short term (after 4hr) Bench top stability or LQCL 0.030 0.0296 98.67 ± 0.32 1.08 0.003 0.0029 96.67 ± 0.03 0.88
MQC 1.600 1.5978 99.86 ± 0.43 0.21 0.030 0.0293 97.67 ± 0.62 2.13
HQC 3.000 2.9847 99.49 ± 7.79 0.26 0.075 0.0746 99.46 ± 0.30 0.41
Long term (after 20days) LQC 0.030 0.0289 96.33 ± 0.16 0.55 0.003 0.0030 100.00 ± 0.02 0.59
MQC 1.600 1.5837 98.98 ± 9.38 0.59 0.030 0.0290 96.67 ± 0.42 1.44
HQC 3.000 2.9466 98.22 ± 50.71 1.72 0.075 0.0741 98.80 ± 0.56 0.76
Auto-sampler (post-preperative stability) LQC 0.030 0.0298 99.38 ± 0.20 0.67 0.003 0.0029 97.29 ± 0.01 0.36
MQC 1.600 1.5933 99.58 ± 7.90 0.50 0.030 0.0292 97.33 ± 0.20 0.69
HQC 3.000 2.9901 99.67 ± 3.22 0.11 0.075 0.0738 98.40 ± 0.42 0.56
Freeze- thaw (after three cycles) LQC 0.030 0.0297 99.11 ± 0.36 1.23 0.003 0.0029 99.33 ± 0.05 1.80
MQC 1.600 1.5961 99.75 ± 4.81 0.3 0.030 0.0293 97.66 ± 0.18 0.63
HQC 3.000 2.9932 99.77 ± 5.8 0.19 0.075 0.0741 98.80 ± 0.48 0.65
Dry extract stability LQC 0.030 0.0287 95.66 ± 1.49 1.55 0.003 0.0028 91.74 ± 1.32 1.44
MQC 1.600 1.5781 98.63 ± 0.18 0.19 0.030 0.0280 91.74 ± 2.62 2.68
HQC 3.000 2.9381 97.93 ± 1.05 1.07 0.075 0.0743 96.79 ± 0.22 0.23
Stock stability solution Pan 97.26 0.51
Ami 96.90 0.63
Omp (IS) 97.17 0.52
Dot (IS) 97.22 0.31