Table 4.

Qualitative analysis

Group A, 5 mL/s Group B, 2.5 mL/s p value
n patients 103 100
Patients with diagnostic CCTA, n (%) 91/103 (88.4%) 89/100 (89%) 0.884
Patients with non-diagnostic CCTA, n (%) 12/103 (11.6%) 11/100 (11%)
Non-diagnostic due to motion artifacts 10/12 (83.3%) 10/11 (90.9%) 0.29
Non-diagnostic due to inadequate enhancement 2/12 (16.7%) 1/11 (9.1%)
Total segments analyzed 1441 1310
Image quality score
Excellent, n (%) 1220/1441 (84.7%) 949/1310 (72.4%)
Good, n (%) 74/1441 (5.1%) 267/1310 (20.4%)
Adequate 3, n (%) 35/1441 (2.4%) 31/1310 (2.4%)
Poor (non-evaluable), n (%) 55/1441 (3.8%) 63/1310 (4.8%)
Poor due to motion artifacts 44/55 (80%) 47/63 (74.6%) 0.486
Poor due to inadequate enhancement 11/55 (20%) 16/63 (25.4%)
Average image quality score per segment (± SD) 3.9 (± 0.4) 3.7 (± 0.5) < 0.001

Data are numbers with percentages in parentheses or mean ± standard deviation. CCTA coronary computed tomography angiography