Skip to main content
. 2021 Jun 20;7:426–440. doi: 10.1016/j.bioactmat.2021.05.048

Fig. 5.

Fig. 5

(a) Tafel curves for Fe, FeMn and FeMnAg tested in HBSS and HBSS+Ca and (b) corresponding corrosion current densities for tested alloys. Error bars represent standard deviation (n = 4).