Skip to main content
. 2021 Aug 24;16(8):e0256029. doi: 10.1371/journal.pone.0256029

Table 1. MRI protocol acquisition parameters.

MRI Scan 3D T1-w image T2-w image (fat sat) T2-w image (no fat sat) Diffusion-weighted B1 Map Multi Flip Angle Spoiled GRE (T1 Mapping) Magnetization Transfer 3D Quantitative DIXON
Orientation Axial Axial Axial Axial Axial Axial Axial Axial
Acquisition Matrix 256 x 208 256 x 208 256 x 208 128 x 104 128 x 104 128 x 104 128 x 104 160 x 132
Field of View [mm] 384 x 312 384 x 312 384 x 312 384 x 312 384 x 312 384 x 312 384 x 312 450 x 372
In Plane Resolution [mm] 1.5 x 1.5 1.5 x 1.5 1.5 x 1.5 3 x 3 3 x 3 3 x 3 3 x 3 1.4 x 1.4
Number of Slices 48 48 48 40 24 48 48 64
Slice Thickness/Slice Gap [mm] 4/0 4/0 4/0 4/0.8 8/0 4/0 4/0 4/0
TR [ms] 4.04 750 386 7600 14310 4.6 2000 9
TE [ms] 1.29; 2.52 105 105 48 2.06 1.96 3.58 1.05; 2.46; 3.69; 4.92; 6.15; 7.38
Flip Angle [degrees] 10 100 100 90 8 20; 16; 12; 8; 4 25 4
Fat Suppression 2 point Dixon SPAIR None SPAIR None None None 6 point Dixon
Miscellaneous b-values: 0, 50, 200, 800 5 flip angles ’MTC’ off & ’MTC’ on
Motion Compensation 1 breath-hold 2 breath-holds 1 breath-hold Respiratory Gated 2 breath-holds 1 breath-hold None 1 breath-hold
Acquisition Time [m:s] 0:12 0:39 0:19 4:08 0:29 0:10 each; 5 acquisitions 2:12 each; 2 acquisitions 0:13