Skip to main content
. 2021 Aug 21;27(31):5232–5246. doi: 10.3748/wjg.v27.i31.5232

Table 3.

Polyp detection between colonoscopists and colonoscopists + computer-assisted detection


Colonoscopists
Colonoscopists + CADe
P value
PDR, % 45.9 48.3 0.06
SSR, % 3.83 4.78 0.50
CRSR, % 9.09 11.5 0.06
Number of polyps, mean ± SD 0.82 ± 1.20 0.90 ± 1.25 < 0.001
Pathology
Non-adenomatous 0.52 ± 0.94 0.58 ± 1.00 0.01
Adenomatous 0.30 ± 0.62 0.32 ± 0.64 0.025
Age
< 50 0.45 ± 0.70 0.51 ± 0.77 0.03
≥ 50 1.12 ± 1.42 1.22 ± 1.47 0.002
Sex
Male 0.96 ± 1.28 1.05 ± 1.36 0.005
Female 0.66 ± 1.07 0.72 ± 1.11 0.01
Location
Proximal 0.35 ± 0.69 0.39 ± 0.76 0.01
Distal 0.46 ± 0.89 0.51 ± 0.90 0.003
Size
≥ 10 mm 0.06 ± 0.28 0.06 ± 0.28 1
6-9 mm 0.18 ± 0.52 0.19 ± 0.52 0.32
≤ 5 mm 0.57 ± 0.95 0.65 ± 1.00 < 0.001
Morphology
Flat 0.67 ± 1.03 0.74 ± 1.08 0.001
Subpedunculated 0.11 ± 0.42 0.12 ± 0.42 0.16
Pedunculated 0.03 ± 0.21 0.03 ± 0.21 1
Indications
Screening 0.76 ± 1.15 0.85 ± 1.21 0.03
Surveillance 1.19 ± 1.42 1.33 ± 1.53 0.03
Diagnosis 0.70 ± 1.10 0.75 ± 1.13 0.03
Colonoscopes
CF-Q290 0.78 ± 1.09 0.87 ± 1.17 < 0.001
CF-Q260 1.04 ± 1.58 1.15 ± 1.56 0.08
CF-Q240 0.83 ± 1.64 0.83 ± 1.64 1
Experience
> 3000 1.24 ± 1.48 1.24 ± 1.48 1
1000-3000 0.79 ± 1.16 0.91 ± 1.26 0.003
< 1000 0.54 ± 0.92 0.62 ± 0.99 0.03
BBPS
< 6 0.59 ± 1.19 0.62 ± 1.19 0.32
≥ 6 0.87 ± 1.19 0.96 ± 1.26 < 0.001
Withdrawal time
< 6 min 0.52 ± 0.97 0.54 ± 0.98 0.16
≥ 6 min 1.13 ± 1.33 1.27 ± 1.39 0.001

CADe: Computer-assisted detection; BBPS: Boston bowel preparation score; PDR: Polyp detection rate; SSR: Sessile serrated adenoma/polyp detection rate; CRSR: Clinical serrated polyp detection rate.