Table IV.
Simulation studies (Departure from MAR assumption): estimates of AUC using methods PG-BRL, SPE-E, SPE-E-A, FI, MSI, IPW.
Assumption |
N = 200 |
||
---|---|---|---|
Model | Method | Bias(True AUC=0.75) | MSE |
MAR | PG-BRL | 0.0146 | 0.0052 |
Threshold | SPE-E | 0.0120 | 0.0077 |
SPE-E-A | 0.0116 | 0.0076 | |
FI | 0.0572 | 0.0073 | |
MSI | 0.0493 | 0.0067 | |
IPW | 0.0055 | 0.0078 | |
NMAR | PG-BRL | −0.0569 | 0.0052 |
SPE-E | −0.0855 | 0.0126 | |
SPE-E-A | −0.0855 | 0.0126 | |
FI | −0.0408 | 0.0050 | |
MSI | −0.0479 | 0.0058 | |
IPW | −0.1184 | 0.0188 |