Skip to main content
. 2021 Aug 3;125(31):8797–8804. doi: 10.1021/acs.jpcb.1c04551

Table 3. Reaction Rate and Estimated Arrhenius Parameters of the TaHeR Thermal Denaturation Process at Various Temperatures in the Absence and Presence of Light.

  dark
light
temperature (°C) k (s–1) Ea (kcal·mol–1) A (s–1) k (s–1) Ea (kcal·mol–1) A (s–1)
63   68.00 ± 0.1 (3.35 ± 0.12) × 1039 (1.37 ± 0.05) × 10–3 52.00 ± 0.1 (1.0 ± 0.1) × 1031
65   (2.25 ± 0.06) × 10–3
67 (1.13 ± 0.08) × 10–4 (3.99 ± 0.06) × 10–3
69   (5.26 ± 0.07) × 10–3
71 (2.74 ± 0.08) × 10–4 (6.83 ± 0.08) × 10–3
73 (5.16 ± 0.07) × 10–4  
75 (1.23 ± 0.07) × 10–3