Imaging information of the included studies

Author Scanners Eye state Repetition time/echo time Thickness (mm) Slice gap (mm) FWHM (mm) Threshold Coordinate
Shan et al. [22] 3.0T Closed 2,000/30 ms 4 0.6 4 Corrected MNI
Zhao et al. [23] 3.0T Closed 2,000/30 ms 4 0.5 4 Corrected MNI
Zhang et al. [24] 3.0T Closed 2,000/29 ms 3 NA 6 Corrected MNI
Wang et al. [8] 3.0T NA 2,000/30 ms 4 0.6 4 Corrected MNI
Gou et al. [25] 1.5T Closed 2,000/40 ms 5 1 4 Corrected MNI
Gao et al. [27] 3.0T NA 2,000/30 ms 4 0.6 4 Corrected MNI
Liu et al. [11] 1.5T NA 2,000/40 ms 5 1 8 Uncorrected MNI
Cui et al. [28] 3.0T Closed 2,000/30 ms 4 0.6 4 Corrected MNI
Gao et al. [26] 1.5T Closed 2,000/40 ms 5 1 6 Corrected MNI
Yu et al. [9] 3.0T NA 2,000/24 ms 3 0 6 Corrected MNI
Liu et al. [12] 1.5T NA 2,000/40 ms 5 1 4 Corrected MNI
Chen et al. [30] 3.0T Closed 580/18 ms 4 0 4 Corrected Talairach
Yan et al. [29] 3.0T Closed 2,500/30 ms 3.5 1 4 Corrected MNI

FWHM: full width at half maximum, MNI: montreal neurological institute