Paper Dataset MR Sequence Hardware Setup Image Processing
Liu, S. 2017 [17] ProstateX
(DICOM)
T2W, DWI, DCE Siemens (Magnetom Trio and Skyra) at 3T without ERC Registration
Mehrtash, A. 2017 [18] ProstateX
(DICOM)
DWI, DCE Siemens (Magnetom Trio and Skyra) at 3T without ERC Normalization
Seah, J. 2017 [27] ProstateX
(DICOM)
T2W, DWI, DCE Siemens (Magnetom Trio and Skyra) at 3T without ERC Normalization
Parra, A. 2018 [28] 2 institutions (DICOM) DWI, DCE (I) Siemens and General Electric at 3T with external pelvic coil; (II) Siemens, Philips, General Electric at 3T and 1.5T with ERC Registration,
Normalization
Jensen, C. 2019 [29] ProstateX
(DICOM)
T2W, DWI, DCE Siemens (Magnetom Trio and Skyra) at 3T without an ERC Normalization
Chen, Q. 2019 [30] ProstateX
(DICOM)
T2W, DWI, DCE Siemens (Magnetom Trio and Skyra) at 3T without an ERC Normalization
Liu, B. 2019 [31] 1 institution DCE General Electric (Signa Excite II) at 1.5T N/A
Zhong, X. 2019 [32] 1 institution T2W, DWI, DCE Siemens (Trio, Verio, Prisma or Skyra) at 3T with pelvic phased-array coil with or without ERC Normalization
Toivonen, J. 2019 [33] 1 institution T2W, DWI Philips (Ingenuity) at 3 T with 32 channel cardiac coils Normalization
Yuan, Y. 2019 [35] (I)1 institution
(II) ProstateX (DICOM)
T2W, DWI (I) N/A; (II) Siemens (Magnetom Trio and Skyra) at 3T without ERC Normalization
Chen, T. 2019 [19] 1 institution T2W, DWI Philips (Intera Achieva) at 3T with 32-channel body phased-array coil N/A
Aldoj, N. 2020 [20] ProstateX
(DICOM)
T2W, DWI, DCE Siemens (Magnetom Trio and Skyra) at 3T without ERC Registration
Normalization
Bernatz, S. 2020 [21] 1 institution
(DICOM)
T2W, DWI, DCE Siemens (Magnetom Prisma FIT) at 3T with 32-channel body coil and spine phased-array coil Limited image manipulation
Litjens, G. 2015 [22] 1 institution T2W, DWI, DCE Siemens (Trio or Skyra) at 3T without ERC N/A
Woznicki, P. 2020 [23] 1 institution T2W, DWI Siemens (Magnetom Skyra and Trio) at 3T with pelvic phased-array coils N/A
Wang, Z. 2018 [24] (I)1 institution
(II) ProstateX
(DICOM)
T2W, DWI (I) Siemens (Magnetom Skyra) at 3T
(II) Siemens (Magnetom Trio and Skyra) at 3T without ERC
Registration
Cao, R. 2019 [25] 1 institution T2W, DWI Siemens (Trio, Skyra, Prisma, Verio) at 3T with and without ERC Registration
Normalization
Schelb, P. 2019 [26] 1 institution T2W, DWI Siemens (Prisma) at 3T with standard multichannel body coil and integrated spine phased-array coil Registration