Skip to main content
. 2021 Aug 4;11(8):1405. doi: 10.3390/diagnostics11081405

Table 2.

Improvement of three AI models against the NIH model for lung area and lung long axis.

Lung Area Error Lung Long Axis Error
Left Lung Right Lung Mean Left Lung Right Lung Mean
ResNet-SegNet 57% 60% 58% 42% 44% 43%
VGG-SegNet 51% 52% 52% 31% 37% 34%
SegNet 22% 19% 21% 5% 13% 4%