Results of the survey regarding brain and spine MRI at baseline.

BASELINE
BRAIN MRI
MRI SEQUENCES Number of Affirmative Answers Percentage Additional Questions Number of Answers Percentage
T1-weighted
2D SE-T1w (pre-Gd) 30 65.2% slice thickness ≤3 mm 8 26.7%
>3 mm 22 73.3%
gap Yes 10 33.3%
No 20 66.7%
3D SE-T1w (pre-Gd) 6 13.0% voxel size <1 mm (isotropic) 3 50.0%
1 mm (isotropic) 3 50.0%
other 0 0.0%
3D GrE-T1w (pre-Gd) 13 28.3% voxel size <1 mm (isotropic) 1 7.7%
1 mm (isotropic) 12 92.3%
other 0 0.0%
2D SE-T1w (post-Gd) 26 56.5% slice thickness ≤3 mm 10 38.5%
>3 mm 16 61.5%
gap Yes 11 42.3%
No 15 57.7%
delay ≤5′ 11 42.3%
>5′ 15 57.7%
3D SE-T1w (post-Gd) 16 34.8% voxel size <1 mm (isotropic) 6 37.5%
1 mm (isotropic) 8 50.0%
other 2 12.5%
delay ≤5′ 11 68.7%
>5′ 5 31.3%
3D GrE-T1w (post-Gd) 23 50.0% voxel size <1 mm (isotropic) 3 13.6%
1 mm (isotropic) 18 81.8%
other 1 4.6%
delay ≤5′ 7 31.8%
>5′ 15 68.2%
T2-weighted
PD/T2w 1 2.2% slice thickness ≤3 mm 1 100%
>3 mm 0 0.0%
gap Yes 0 0.0%
No 1 100.0%
2D T2w 30 65.2% slice thickness ≤3 mm 15 50.0%
>3 mm 15 50.0%
gap Yes 13 43.3%
No 17 56.7%
3D T2w 3 6.5% voxel size <1 mm (isotropic) 1 33.3%
1 mm (isotropic) 1 33.3%
other 1 33.3%
2D FLAIR 12 26.1% slice thickness ≤3 mm 4 33.3%
>3 mm 8 66.7%
gap Yes 2 16.7%
No 10 83.3%
3D FLAIR 40 87.0% voxel size <1 mm (isotropic) 10 25.0%
1 mm (isotropic) 24 60.0%
other 6 15.0%
Sequences for cortical lesions detection
2D DIR 3 6.5% slice thickness ≤3 mm 2 66.7%
>3 mm 1 33.3%
gap Yes 1 33.3%
No 2 66.7%
3D DIR 14 30.4% voxel size <1 mm (isotropic) 2 14.3%
1 mm (isotropic) 10 71.4%
other 2 14.3%
2D PSIR 4 8.7% slice thickness ≤3 mm 2 50.0%
>3 mm 2 50.0%
gap Yes 2 50.0%
No 2 50.0%
3D PSIR 3 6.5% voxel size <1 mm (isotropic) 0 0.0%
1 mm (isotropic) 3 100%
other 0 0.0%
None 23 50.0%
Sequences for optic nerves evaluation
STIR-T2w 34 73.9% slice thickness ≤3 mm 31 91.2%
>3 mm 3 8.8%
gap Yes 10 29.4%
No 24 70.6%
Post-Gd Fat-Sat T1w 22 47.8% slice thickness ≤3 mm 22 100%
>3 mm 0 0.0%
gap Yes 5 22.7%
No 17 77.3%
None 8 17.4%
Additional sequences
DWI 44 95.6%
GrE-T2* 17 37.0% slice thickness ≤3 mm 4 23.5%
>3 mm 13 76.5%
gap Yes 8 47.1%
No 9 53.9%
2D SWI 12 26.1% slice thickness ≤3 mm 9 75.0%
>3 mm 3 25.0%
gap Yes 2 16.7%
No 10 83.3%
3D SWI 15 32.6% voxel size <1 mm (isotropic) 4 26.7%
1 mm (isotropic) 9 60.0%
other 2 13.3%
None 1 2.2%
SPINE MRI
MRI SEQUENCES Number of Affirmative Answers Percentage Additional Questions Number of Answers Percentage
T2-weighted
T2w 41 89.1% acquisition plane sagittal 41 100%
axial 17 41.5%
slice thickness on sagittal acquisition ≤3 mm 39 95.1%
>3 mm 2 4.9%
gap on sagittal acquisition Yes 14 34.1%
No 27 65.9%
PDw 2 4.3% acquisition plane sagittal 2 100.0%
axial 0 0.0%
slice thickness on sagittal acquisition ≤3 mm 1 50.0%
>3 mm 1 50.0%
gap on sagittal acquisition Yes 2 100.0%
No 0 0.0%
STIR-T2w 42 91.3% acquisition plane sagittal 42 100.0%
axial 2 4.7%
slice thickness on sagittal acquisition ≤3 mm 38 90.5%
>3 mm 4 9.5%
gap on sagittal acquisition Yes 14 33.3%
No 28 66.7%
T1-weighted and inversion recovery
PSIR 2 4.3% acquisition plane sagittal 2 100%
axial 0 0.0%
slice thickness on sagittal acquisition ≤3 mm 2 100%
>3 mm 0 0.0%
gap on sagittal acquisition Yes 1 50.0%
No 1 50.0%
2D SE-T1w (pre-Gd) 26 56.5% acquisition plane sagittal 26 100%
axial 3 11.5%
slice thickness on sagittal acquisition ≤3 mm 23 88.5%
>3 mm 3 11.5%
gap on sagittal acquisition Yes 11 42.3%
No 15 57.7%
3D GrE-T1w (pre-Gd) 2 4.3% acquisition plane sagittal 2 100%
axial 1 50.0%
slice thickness on sagittal acquisition ≤3 mm 2 100%
>3 mm 0 0.0%
gap on sagittal acquisition Yes 0 0.0%
No 2 100%
2D SE-T1w (post-Gd) 42 91.3% acquisition plane sagittal 41 100%
axial 13 31.7%
slice thickness on sagittal acquisition ≤3 mm 37 90.2%
>3 mm 4 9.8%
gap on sagittal acquisition Yes 16 39.0%
No 25 61.0%
delay ≤5′ 19 47.5%
>5′ 21 52.5%
3D GrE-T1w (post-Gd) 3 6.5% acquisition plane sagittal 2 66.7%
axial 2 66.7%
slice thickness on sagittal acquisition ≤3 mm 2 100%
>3 mm 0 0.0%
gap on sagittal acquisition Yes 0 0.0%
No 2 100%
delay ≤5′ 1 33.3%
>5′ 2 66.7%

SE = spin-echo; GrE = gradient-echo; FLAIR = fluid attenuated inversion recovery; DIR = double inversion recovery; PSIR = phase sensitive inversion recovery; Fat-Sat = fat saturated; DWI = diffusion weighted imaging; SWI = susceptibility weighted imaging; PD = proton density; STIR = short tau inversion recovery; Gd = gadolinium.