Table 3.

The average coupling strengths among the 10 best parameter sets in model framework applied to awake data

Noise regime Ind. GC Inh. (wMG) Shared GC Inh. (wGc) MC excit. (wGM)
Smaller σ 8.61 2.87 3.45
σvary in time 8.92 1.73 4.49
Larger σ 7.22 2.49 6.35

The values are similar, having the same relationship as with anesthetized data: wMG>wGM>wGc (see Table 1).