Skip to main content
. 2021 Aug 9;21(16):5387. doi: 10.3390/s21165387

Table 7.

Drip irrigation network evaluation calculating coefficient of variation (CV), Christiansen’s coefficient of uniformity (CU), distribution uniformity (DU), and flow rate variation (qvar) at 1 bar operating pressure.

Lateral Line CV CU, % DU, % qvar, %
1 0.038 98.43 96.67 6.45
2 0.040 98.23 95.25 9.15
3 0.029 99.13 95.67 7.72
4 0.041 99.55 94.62 9.27
Mean 0.037 98.83 95.55 8.14