Table 3.
Results of tensile tests on PHBHV/MIS composites considering different fiber content (0, 5, 10, 20, 30 wt %). The standard deviation values are also presented.
Samples | Tensile Modulus [MPa] | Tensile Strength [MPa] | Ultimate Strain [%] |
---|---|---|---|
PHBHV | 889 ± 41 | 22.0 ± 0.48 | 9.9 ± 1.1 |
PHBHV95MIS5 | 1074 ± 44 | 17.0 ± 1.54 | 4.2 ± 0.7 |
PHBHV90MIS10 | 1238 ± 74 | 16.8 ± 1.67 | 4.4 ± 0.9 |
PHBHV80MIS20 | 1267 ± 90 | 15.8 ± 0.77 | 3.9 ± 0.2 |
PHBHV70MIS30 | 1891 ± 172 | 16.9 ± 1.03 | 3.3 ± 0.7 |