Table 7.
Materials |
× 105
(J·g−1·K−4) |
(J·g−1·K−3) | (J·g−1·K−2) | (J·g−1·K−1) |
(J·g−1·K−1) |
Temperature Range (K) | |
---|---|---|---|---|---|---|---|
CA | 3.6535 ± 6.9456 | −0.0310 ± 0.0597 | 8.7941 ± 17.1184 | −830.51 ± 1635.1 | 0.9871 | 0.0140 | [278; 296] |
MA | 0.7738 ± 0.1805 | −0.0066 ± 0.0016 | 1.8873 ± 0.4805 | −179.18 ± 47.657 | 0.9991 | 0.0068 | [278; 318] |
PA | 0.8506 ± 0.1354 | −0.0074 ± 0.0012 | 2.1770 ± 0.3727 | −211.51 ± 37.566 | 0.9981 | 0.0112 | [278; 328] |
CA/MA | 22.996 ± 8.9840 | −0.1940 ± 0.0761 | 54.563 ± 21.509 | −5114.5 ± 2025.0 | 0.9915 | 0.0110 | [278; 291] |
CA/PA | 22.856 ± 4.8510 | −0.1932 ± 0.0412 | 54.445 ± 11.661 | −5113.0 ± 1100.0 | 0.9949 | 0.0077 | [278; 290] |
* Standard uncertainty given for a 95% confidence interval for our measurements is u(p) = 10 kPa. The uncertainty given for the fitting parameter is given for a 95% confidence interval.