Skip to main content
. 2021 Aug 20;14(16):4707. doi: 10.3390/ma14164707

Table 13.

Comparison of PCM in the temperature range of application.

Materials Tm (K) ΔHm (J·g−1) ρ (kg·m−3) CP (J·g−1·K−1) k (W·m−1·K−1) E (kWh·m−3)
Sol. (Tamb) Liq. (Tm) Sol. Liq. Sol.
CA/MA 297.29 137.3 942.8 895.3 1.83–2.05 2.40 0.2717 34.15
CA/PA 299.25 148.14 989.2 887 1.85–2.05 2.12 0.2358 36.50
CaCl2-6H2O [44] 302.75 191 1802 1562 1.42 2.10 1.088 82.87
PureTemp 25 [33] 298.15 187 950 860 1.99 2.29 44.67