Skip to main content
. 2021 Aug 3;14(8):762. doi: 10.3390/ph14080762

Table 2.

Technical aspects of 2-[18F]FDG PET/CT in the included studies.

Authors Hybrid Imaging Modality and PET/CT Scanner Fasting before 2-[18F]FDG Injection Mean Injected 2-[18F]FDG Activity Time Interval between 2-[18F]FDG Injection and Image Acquisition Image Analysis
Adin et al. [10] NR 4–6 h NR 1 h Visual
Bernstine et al. [11] PET/CT (contrast enhanced CT) using GE Discovery 710 NR 185–370 MBq NR Visual and semi-quantitative (SUVmax)
Cohen et al. [12] PET/CT (contrast enhanced CT) using GE Discovery 690 or GE Discovery MI NR 3.7 MBq/kg 1 h Visual and semi-quantitative (SUVmax)
Cohen et al. [13] PET/CT (contrast enhanced CT) using GE Discovery 690 or GE Discovery MI NR 3.7 MBq/kg 1 h Visual and semi-quantitative (SUVmax)
Eifer et al. [14] PET/CT (low dose CT) using Philips Vereos 2–6 h 5.18 MBq/kg 1 h Visual and semi-quantitative (SUVmax)
Eshet et al. [15] PET/CT (low dose CT) using Philips Vereos NR NR NR Visual and semi-quantitative (SUVmax)
Schroeder et al. [16] PET/CT (low dose CT) using GE Discovery 690, GE Discovery 710, GE Discovery MI or Siemens Biograph Vision 600 11 h 437 MBq 1 h Visual and semi-quantitative (SUVmax)
Shin et al. [17] PET/CT (low dose CT) using GE Discovery STE At least 6 h 5 MBq/kg 1 h Visual and semi-quantitative (SUVmax)
Skawran et al. [18] PET/CT (low dose CT) using GE Discovery MI At least 4 h 1.5–3.1 MBq/kg 1 h Visual and semi-quantitative (SUVmax)

Legend: 2-[18F]FDG = fluorine-18 fluorodeoxyglucose; CT = computed tomography; h = hour; MBq = megabecquerel; NR = not reported; PET/CT = positron emission tomography/computed tomography; SUVmax = maximal standardized uptake value.