Wearable Cutaneous Haptic Interface (WCHI) [40] |
Finger |
Parkinson’s Disease |
Three degrees of freedom to measure disease conditions, such as tremor and bradykinesia. |
Smart Electro-Clothing Systems (SeCSs) [41] |
Heart |
Health Monitoring |
Surface electromyography (sEMG); HR, heart rate variability. |
Xsens DOT [42] |
All over the body |
Healthcare, sports |
Osteoarthritis |
5DT data glove [43] |
Fingers and wrist |
Robust Hand Motion Tracking |
Fibre optic sensors measure flexion and extension of the Interphalangeal (IP), metacarpophalangeal (MCP) joints of the fingers and thumb, abduction and adduction, and the orientation (pitch and roll) of the user’s hand. |
Neofect Raphael data glove [44] |
Fingers, wrist and forearm |
Poststroke patients |
Accelerometer and bending sensors measuring flexion and extension of finger and thumb. |
Stretchsense data glove [45] |
Hand motion capture |
Gaming, augmented and virtual reality domains, robotics and the biomedical industries. |
Flexion, extension of fingers and thumb. |
Flex Sensor (Data glove) [46] |
Finger |
Rheumatoid Arthritis (RA), Parkinson’s disease and other neurological conditions/rehabilitative requirements. |
Flexion and extension of the (IP), (MCP) joints of the fingers and thumb and the abduction and adduction movements. |
X-IST Data Glove [47] |
Hand and fingers |
Poststroke patients |
Five bend sensors and five pressure sensors measure MCP, PIP finger and thumb movement. |
MoCap Pro (Smart Glove) [48] |
Hand and fingers |
Stroke |
Capture bend of each MCP and proximal interphalangeal (PIP) joint. |
Textile-Based Wearable Gesture Sensing Device [49] |
Elbow and knee |
Musculoskeletal disorders |
Flexion angle of elbow and knee movements |
VICON system [50] |
Shoulder and elbow |
Musculoskeletal disorders |
Humerothoracic, scapulothoracic joint angles and elbow kinematics. |
Goniometer-Pro [51] |
Knee |
Stroke |
Passive flexion of knee. |
Smart Garment Sensor System [52] |
Leg |
Strain sensor |
Lower limb joint position analysis. |
Fineck [53,54] |
Neck |
Monitor neck movements and respiratory frequency. |
Flexion-extension and axial rotation repetitions, and respiratory frequency. |
SMART DX [55] |
All over the body |
Gait clinical assessment and multifactorial movement analysis. |
Dynamic analysis of muscle activity, postural analysis, motor rehabilitation. |
ViMove [56] |
Neck, lower back and knee |
Movement and Activity Recognition in sports and clinical monitoring. |
Flexion-extension and axial rotation. |
Dubbed Halo [57] |
Wrist |
Voice monitoring application called ‘Tone’. |
Detect the “positivity” and “energy” from the human voice. |
Polysomnography sensors [58] |
Chest, hand, leg and head |
Identify sleep apnoea |
Breathing volume and heart rate. |
Pulse oximetry [59] |
Finger |
Pulmonary disease |
Monitor oxygen saturation, respiratory rate, breathing pattern and air quality. |
TZOA [60] |
Textile |
Respiratory disease |
Measure air quality and humidity. |
Eversense Glucose Monitoring, Guardian Connect System and Dexcom CGM [61] |
Hand |
Diabetes |
Glucose level monitoring. |