Skip to main content
. 2021 Aug 18;21(16):5571. doi: 10.3390/s21165571

Table 4.

Comparison in terms of accuracy, number of features selected, and computation time while experimenting on four disease datasets with and without applying our proposed feature selection method.

Dataset Accuracy (%) Obtained by the Proposed Method (with Feature Selection) Accuracy (%) on the Entire Dataset (without Feature Selection)
Original #Features #Features Selected Accuracy (%) Computation Time (s) KNN SVM NB Computation Time (s)
Arrhythmia 279 3 94.50 238 63.06 75.44 67.71 42.8
Leukemia 5147 4 100 358 87.67 88.92 100 43.9
DLBCL 7070 4 100 545 84.10 75.35 78.75 47.5
Prostate cancer 12,532 3 100 782 85.36 84.36 62.54 55.6