Table 4.

Sensitivities and specificities of the TIRADS systems (TIRSYS) and investigators’ opinion (PERS) according to the size of the nodules

Maximal diameter of the lesion
<1 cm
1–2 cm
2–3 cm
≥3 cm
sensitivity, % (CI)3 specificity, % (CI) sensitivity, % (CI) specificity, % (CI) sensitivity, % (CI) specificity, % (CI) sensitivity, % (CI) specificity, % (CI)
TIRSYS-A1 0 (0–1) 100.0 (96.5–100) 84.8 (81.9–87.5) 44.5 (41.1–47.8) 96.4 (93.5–98.3) 15.5 (12.7–18.6) 90.0 (86.4–92.9) 19.6 (17.3–22.1)
TIRSYS-B1 74.3 (69.4–78.8) 13.3 (7.5–21.4) 84.8 (81.9–87.5) 44.5 (41.1–47.8) 97.9 (95.4–99.2) 8.9 (6.7–11.5) 94.0 (91–96.2) 10.2 (8.5–12.2)
PERS2 71.4 (59.4–81.6) 5.5 (0.1–23.8) 88.0 (81.2–93.0) 31.4 (24.6–38.9) 92.9 (82.7–98.0) 21.8 (14.8–30.4) 97.1 (90.1–99.7) 13.8 (9.5–19.1)
p (TIRSYS-A vs. PERS) <0.001 <0.001 0.35 0.01 0.22 0.09 0.05 0.05
p (TIRSYS-B vs. PERS) 0.62 0.27 0.35 0.01 0.04 <0.001 0.29 0.12
p (TIRSYS-A vs. TIRSYS-B) 0.001 <0.001 1.0 1.0 0.31 <0.001 0.05 <0.001

In TIRSYS-A, the stricter suggestion of TIRADS was taken into account; FNA was indicated neither in nodules <1 cm nor in the very low-suspicion group of ATA. In TIRSYS-B, the permissive suggestions of TIRADS have been considered; FNA was indicated both in those subcentimeter nodules which belonged to the highest TIRADS category and in the very low-suspicion group of ATA if the nodule was >2 cm.

1

TIRSYS means the combined results of TIRADS of 5 professional societies, that is, the AACE/ACE/AME [13], the ATA [12], the ACR [14], the ETA [15], and the KSTR [16].

2

Personal suggestions of the investigators.

3

CI means 95% confidence interval.