Uncertainty budget for the half-life determined by HPGe at NPL using the summed net areas of the 238 keV, 241 keV, and 583 keV full-energy peaks.

Component uA/A/% n Propagation Factor uT1/2/T1/2/%
Standard deviation of the residuals 0.18 221 0.038 0.0066
Fitting 0.30 1 0.399 0.12
Stability 0.10 1 0.399 0.040
Dead time/Pile-up 0.10 1 0.399 0.040
Background correction 0.0050 1 0.399 0.0020
228Th correction 0.013 1 0.399 0.0051

Combined standard uncertainty, uc 0.13