Meteorological measurements |
|
MaxiMet GMX 541 compact weather station (Gill Instruments, UK) |
Range: −40–70 °C |
Accuracy: ±0.3 °C |
|
Range: 0%–100% |
Accuracy: ±2% |
|
Range: 0.1–60 m/s |
Accuracy: ±3% |
|
Range: 0–1,600 W/m2
|
Accuracy: ±1 W/m2
|
Skin-based thermo-physiological quantity |
|
Dermal combo probes (Cortex Technology, Denmark) |
Range: 0–50 °C |
Accuracy: ±0.1 °C |
A310 Infrared thermographic camera (FLIR®, USA) |
Range: 20–350 °C |
Accuracy: ±0.1 °C |
|
Conductance (single frequency) electrode in flat-faced probe (Cortex DermaLab® System, Denmark) |
Range: 0–9,999 μS |
Accuracy: ±5% |
|
Vapor diffusion gradient probe (Cortex DermaLab® System, Denmark) |
Range: 0–250 g/m2/h |
Accuracy: ±5% |
|
PHFS-01 heat flux sensors (FluxTeq, USA) |
Range: +/- 150 kW/m2
|
Accuracy: ±5% |
Microclimate inside the PFM |
|
Maxim-integrated iButtons (Digi-Key Electronics, USA) |
Range: 40–85 °C |
Accuracy: ±0.1 °C |
|
Range: 0–100% |
Accuracy: ±2.5% |
|
K33 ELG 10,000 ppm CO2 sensor (CO2METER, USA) |
Range: 10,000 ppm |
Accuracy: ±3% |
|
UV Flux Oxygen Smart Senor (CO2METER, USA) |
Range: 0–25% |
Accuracy: ±2% |