Most relevant ECG‐based features for automatic seizure detection

DiffHeartBeatPrePost Difference of heart rate, pre‐event vs. post‐event
DiffMeanRRIntervalPrePost Difference of average RRI, pre‐event vs post‐event
DiffEntropyRRIntervalPrePost Difference of entropy of RRI, pre‐event vs post‐event
DiffCVIPrePost Difference of CVI, pre‐event vs post‐event
DiffCSIPrePost Difference of CSI, pre‐event vs post‐event
DiffRRIPSDVLFPrePost Difference of PSD of RRI in VLF, pre‐event vs post‐event
DiffRRIPSDLFPrePost Difference of PSD of RRI in LF, pre‐event vs post‐event
DiffRRIPSDHFPrePost Difference of PSD of RRI in HF, pre‐event vs post‐event
DiffRRIPSDTotalPowerPrePost Difference of PSD of RRI in all freq., pre‐event vs post‐event
DiffRRIPSDPowerRatioPrePost Difference of PSD of RRI in power ratio, pre‐event vs post‐event
DiffNN50PrePost Difference of NN50, pre‐event vs post‐event
DiffPNN50PrePost Difference of PNN50, pre‐event vs post‐event
ecgRelHR Relative heart rate fold change