Skip to main content
. 2000 Oct 23;2000(4):CD001921. doi: 10.1002/14651858.CD001921

Balzer 1998.

Methods Monocentric, different surgeons 
 Randomisation: blocks of 50 changing the operative method on a monthly term 
 Sample size: 300 for each group 
 Recruitment period: 1 year 
 Mean follow up: 24 months 
 Lost to follow up: 22 (3.9%); 9 in Dacron patch group and 13 in eversion CEA
Participants 564 patients (34% female) 
 Mean age 66 years 
 No patients randomised twice
Interventions Two groups 
 Control: Dacron patch CEA 
 Treatment: 286 eversion CEA and 278 Dacron patch CEA
Outcomes Perioperative (in hospital) death 
 Perioperative (in hospital) stroke 
 Recurrent carotid stenosis 
 Late stroke 
 Late death 
 Perioperative local complications: neck hematoma
Notes Exclusions: repeated CEA, bilateral CEA
Risk of bias
Bias Authors' judgement Support for judgement
Allocation concealment? Unclear risk B ‐ Unclear