Skip to main content
. 2021 Aug 10;6(4):e00793-21. doi: 10.1128/mSystems.00793-21

FIG 3.

FIG 3

Quantitative interpretation of the wastewater data. (A) Snapshot of the sewer network showing the two autosamplers by isolation unit AS017 is downstream of sampler AS019 (associated with the isolation dorm). The mean Cq values of the daily samples from the two samplers are shown in the bottom panel. (B) Mean viral gene copies per liter of sewage collected daily from the isolation dorms (sampler AS019) compared to the number of students in isolation/quarantine on the same day. (C) Measured daily caseload data compared to the predicted filter output with a 1-day sampling delay for all active on-campus samplers (mean, 0.67; root mean square error [RMSE], 1.5). (D). Measured daily caseload data compared to the predicted filter output with a 1-day sampling delay for the isolation unit sampler AS019 (mean 0.80, RMSE 6.8). Maps are the intellectual property of Esri and its licensors and are used under license. Copyright © 2021 Esri and its licensors. All rights reserved.