Skip to main content
. 2021 Aug 26;13(4):216–225. doi: 10.4047/jap.2021.13.4.216

Table 4. Maximum principal stress (MPa) on the implant-bridge system (unit: MPa).

Occlusion #13 screw #15 screw #13 abutment #15 abutment Crown Bone
Canine guidance 15° 154 150 158.36 101.16 58.59 27.542
Canine guidance 30° 167 153 242.25 170.64 110.52 39.179
Group function 15° 182 218 507.32 568.66 107.59 92.788
Group function 30° 220 273 854.95 940.45 167.34 137.5