Table 9.

Comparison of manual electrocardiographic detection of atrial fibrillation with nurse electronic medical record heart rhythm annotation for atrial fibrillation.a

Nurse charting Manual atrial fibrillation status
Atrial fibrillation No atrial fibrillation Total
Atrial fibrillation 24 9 33
No atrial fibrillation 1 16 17
Total 25 25 50

aThe sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 96% (95% CI 80%-100%), 64% (95% CI 43%-82%), 73% (95% CI 61%-82%), 94% (95% CI 70%-99%), and 80% (95% CI 66%-90%), respectively.