Skip to main content
. 2021 Aug 13;9:725310. doi: 10.3389/fpubh.2021.725310

Table 5.

Maximum specific energy absorption normalized by an ICNIRP-prescribed power density limit of 2 W/m2 for general exposures to various human model.

Model Ungrounded case Grounded case
Maximum SA (nJ/kg) SA at the ankle (nJ/kg) Maximum SA (nJ/kg) SA at the ankle (nJ/kg)
Male (TARO) 0.401 (hand) 0.119 0.401 (hand) 0.182
Female (HANAKO) 0.127 (neck) 0.117 0.199 (ankle) 0.199
7-year child 0.437 (hand) 0.139 0.436 (hand) 0.223
5-year child 0.173 (hand) 0.138 0.237 (ankle) 0.237
3-year child 0.243 (hand) 0.154 0.267 (ankle) 0.267