Skip to main content
. 2021 Sep 8;66:102–108. doi: 10.1016/j.jcrc.2021.08.012

Table 3.

Results of subgroup analysis using ROX index for predicting HNFC failure.

Categories Sensitivity (95% CI) Specificity (95% CI) sAUC (95% CI) DOR (95% CI) I2
Time from onset to ROX- index assessment
All studies 0.70 (0.59 – 0.80) 0.79 (0.67 – 0.88) 0.81 (0.77 – 0.84) 9 (5 – 16) Sensitivity: 86.05%
Specificity: 85.03%
Within 6 h 76 (0.65 – 0.84) 0.74 (0.62 – 0.83) 0.81 (0.78 – 0.84) 9 (5 –15) Sensitivity: 77.15%
Specificity: 75.79%



Cut-off value
Cut-off 5 0.65 (0.48 – 0.79) 0.75 (0.59 – 0.87) 0.76 (0.72 – 0.80) 6 (4 – 9) Sensitivity: 77.01%
Specificity: 84.38%
Cut-off >5 0.77 (0.65 – 0.86) 0.85 (0.67 – 0.94) 0.87 (0.83 – 0.89) 19 (11 – 35) Sensitivity: 76.53
Specificity: 89.15%

sAUC – summary area under the curve, DOR- diagnostic odds ratio, CI- confidence interval.