Table 1.
Mild approach with low risk | |||||
---|---|---|---|---|---|
Author and year | Study design and title | Location in arch | Abutment material/type | Restoration material | Technique andretrieval methodology |
Barbosa et al., 2014[7] | DescriptiveThe cotton driver: An alternative technique for removing fractured screw fragments | Not available | Titanium abutment | Not available | Modified cotton swabPressing the cotton swab into the implant head and twist the fractured abutment screw slowly counter clockwise |
Yang and Wu 2019[8] | DescriptiveA technique to retrieve a fractured implant abutment screw by using a screwdriver fashioned from a needle | Not available | Prefabricated Titanium abutment | Not available | Modified hypodermic needleAppropriate sized needle is bending to form screwdriver. After engaging the fractured end, turned counter clockwise for removal |