Example initial EBRT treatment plan/chart check items for medical physicists

Sections Recommended Optional
Plan integrity check
Patient name/MRN/DOB
Isocenter/initial reference point matched with simulation doc Dose calculation algorithm (per institutional policy)
Isocenter/initial reference point matched with the patient skin marks
Isocenter shift documented
Rx dose in plan matched with Rx in RO‐EMR
Field parameters (MUs, dose, field size, collimator, gantry, and MLC positions) reasonable or following local policy
Calculation dose grid included all critical contours
Beams associated with appropriate isocenter
If multiple isocenters are used, clearly labeling of each isocenter
3D field shapes appropriate for physician intent (3D plans only)
Plan quality and dose metrics reasonable (if applicable)
Beam name following institutional convention
Beam modification (bolus) noted and documented
Check Beam clearance (potential collision)
Correct CT dataset used
ROI density override appropriate
Deliverability of beams (minimum MU for EDW, and maximum MU allowed for high dose, or high dose box checked, errors and warning messages addressed)
Couch included/excluded correctly
Implanted electronic device dose documented (if applicable)
Prior treatment dose added and plan sum appropriate (if applicable)
Report conformal index (SRS/SBRT plan only)
Secondary dose calculation difference <5%
Preparation in RO‐EMR
Rx in RO‐EMR in accordance with Table 3 Setup beams associated with the same treatment isocenter
Rx approved by physician Image fusion/registration completed and documented
Plan approved by physician and physicist (or in plan document) Patient‐specific QA reviewed
All field parameters input (or associated) correctly and approved (if using third party system) Special physics consult documented (if applicable)
Site setup instruction (treatment positions, bolus, motion management, etc) are set correctly Planned for a scheduled treatment machine
Reference CT input with correct isocenter and include relevant targets and ROIs Immobilization appropriate
DRRs associated and approved (if use a third party system) Dose tracking point (volume) matched Rx in RO‐EMR
Tolerance table set correctly Created QCL/task for therapy check
CBCT/IGRT alignment instruction presence
Treatment schedule (eg, daily, BID) is in agreement with Rx
Dose tracking set correctly (if applicable)
Special instructions as needed (eg, surface guided imaging parameters, breath‐hold threshold)

Abbreviations: DIBH, deep inspiration breath hold; DOB, date of birth; DRR, digitally reconstructed radiograph; EDW, enhanced dynamic wedge; IGRT, image‐guided radiotherapy; KVCBCT, Kilo‐voltage cone beam CT; MU, monitor unit; MVCBCT, Mega‐voltage cone beam CT; QCL, quality‐check‐list; RO‐EMR; Radiation specific electron medical record system; ROIs, regions‐of‐interest; Rx, prescription; SID, source‐imager distance; SSD, source‐skin distance; Tx, treatment.