Skip to main content
. 2021 Mar 2;59(4):272–282. doi: 10.2486/indhealth.2020-0199

Table 2. Proportions of passing user seal checks (USCs) and Isoamyl acetate (IAA) fit tests by respirator brands.

Variable Seal check IAA Fit test Kappa
(k)
95% CI for k


Brand/Size Pass
N(%)
Fail
N(%)
Pass
N(%)
Fail
N(%)
Lower Upper
3M (M) 11
(26.80)
30
(73.20)
9
(22.0)
32
(78.0)
0.87 0.66 1.0
MSA (M) 5
(12.20)
36
(87.80)
1
(2.40)
40
(97.60)
0.30 0.0 0.79
DUO (OSFA) 5
(12.20)
36
(87.80)
1
(2.40)
40
(97.60)
0.30 0.0 0.72
Climax (OSFA) 2
(4.90)
39
(95.10)
2
(4.90)
39
(95.10)
0.47 -0.04 1.0
S 4
(9.76)
37
(90.24)
2
(4.90)
39
(95.10)
0.64 0.0 1.0
M 7
(17.10)
34
(82.90)
6
(14.60)
35
(85.40)
0.91 0.64 1.0
AoSafety
L 6
(14.60)
35
(85.40)
4
(9.76)
37
(90.24)
0.77 0.30 1.0
All
sizes
17
(41.50)
24
(58.50)
12
(29.30)
29
(70.70)
0.74 0.54 0.91

OSFA: One size fits all

S: Small

M: Medium

L: Large