Skip to main content
. 2021 Sep 10;100(36):e27020. doi: 10.1097/MD.0000000000027020

Table 3.

Results and statistics of cardiac outputs calculated by Fick method and measured through thermodilution.

Higher-FIO2 group (FIO2 > 0.85, n = 21) Lower-FIO2 group (FIO2 < 0.7, n = 21)
Fick-CO TD-CO Fick-CO TD-CO
Mean ± SD 4.8 ± 1.4 3.6 ± 1.5 4.5 ± 1.0 3.6 ± 0.6
Pearson Correlation (P value) 0.475 (.03) 0.490 (.02)