Skip to main content
. 2021 Sep 9;11:18017. doi: 10.1038/s41598-021-97520-z

Table 3.

Comparison of the CI and HI for the targets between SEB-HFWBI and SIB-HFWBI plans in the same position (mean).

Parameters SEB-HFWBI SIB-HFWBI T-value P-value
Supine
PTVSupine-TB
CI 0.48 ± 0.06 0.58 ± 0.07  − 8.114 0.000
HI 0.09 ± 0.01 0.10 ± 0.01  − 6.552 0.000
PTVSupine-WB
CI 0.63 ± 0.07 0.66 ± 0.06  − 13.356 0.000
PTVSupine-WB-PTVSupine-TB
HI 0.31 ± 0.02 0.19 ± 0.02 34.467 0.000
Prone
PTVProne-TB
CI 0.46 ± 0.08 0.54 ± 0.09  − 8.114 0.000
HI 0.09 ± 0.02 0.10 ± 0.01  − 6.552 0.000
PTVProne-WB
CI 0.68 ± 0.07 0.71 ± 0.07  − 13.356 0.000
PTVProne-WB-PTVProne-TB
HI 0.31 ± 0.02 0.21 ± 0.02 34.467 0.000

TB tumor bed, PTVTB planning target volume for the TB, WB whole breast, PTVWB planning target volume for the WB, SIB simultaneous integrated boost, SEB sequential integrated boost, HFWBI hypofractionated whole-breast irradiation, CI conformal index, HI homogeneity index, PTVsupine-WB-PTVsupine-TB the target volume obtained by subtracting the PTVTB from the PTVWB in supine position, PTVprone-WB-PTVprone-TB the target volume obtained by subtracting the PTVTB from the PTVWB in prone position.