Skip to main content
. 1999 Feb;37(2):367–370. doi: 10.1128/jcm.37.2.367-370.1999

TABLE 3.

Analytical sensitivity of tests for detection of antibodies to HIV-1 and HIV-2 with samples positive for HIV-1 by EIAa

Test Analytical sensitivity
Serum samples
Whole-blood samples
2P032S 2P043S 3P001S 3P003S 3P019S 2P033W 2P044W 3P002W 3P004W 3P020W
Determine HIV-1/2 213b 212 212 212 214 213 211 211 211 212
PA 212 212 214 211 214  NAc NA NA NA NA
Latex agglutination 24 24 25 23 24 NA NA NA NA NA
Hemo-Strip HIV-1/2 NA NA NA NA NA 21 22 24 24 25
a

Abbott HIV-1/2 3rd Gen. Plus. 

b

The endpoint was detected by the twofold dilution method with a negative serum sample for the serum samples and a negative whole-blood sample for the whole-blood samples. 

c

NA, not applicable.