Table 3.
Molded Parts | Material Trade Name |
MIM Machine and Parameter |
Ultrasound Parameter | Results | Ref. | |
---|---|---|---|---|---|---|
Concave Lens | Polycarbonate (PC) TARFLON A2200 |
AZ700 Compression force: 980 kN Cooling time: 120 s |
f = 19 kHz Amplitude: 0–11 μm Oscillation: 0–60 s |
Replication properties ↑ Residual optical strain ↓ |
[18] | |
Micro-Tensile Sample | Polypropylene (PP) PPH 734-52 RNA |
ARBURG Allrounder 320C Clamping force: 600 kN |
f: 20 kHz Max. power: 800 W Max. amplitude: 11 μm |
Weld line strength ↑ | [40] | |
A Flat Sample | Polycarbonate (PC) Teijin AD5503 |
ARBURG Allrounder 320C Clamping force: 600 kN |
f: 19 kHz Max. power: 2 kW Max. amplitude: 15 μm |
Pressure loss ↓ Residual stress ↓ Filling efficiency ↑ Thickness of the frozen layer ↓ |
[31,39] | |
Fresnel Lenses | COC Zeonex 480R |
FANUC ROBOT S-2000i 50B | f: 27 kHz | Filling performance ↑ Symmetric deviation ↑ |
[45] | |
Microchannel Array | PMMA HT50Y |
DQ-1500T-A Clamping force: 15,000 kN |
f: 28 kHz Max. amplitude: 10 μm |
Average weight/height ↑ standard deviation ↑ replication rate ↑ |
[38] | |
Micro-Needle Array | Polymethylmethacrylate (PMMA) JPC Novatec BC06N |
FANUC ROBOT S-2000i 50B | f: 55 kHz Max. amplitude: 28 μm |
Filling rate ↑ Material properties ↑ |
[49] |