Table 3.

Characteristic values of the electrical sensor performance derived from the dynamic tensile testing of the ShSFC. The initial resistance was calculated as the mean value from five samples.

Range of Strains (%) 0–50 25–75
Drift (%) 63 22
Buckling at strains (%) 24 49
Initial Resistance (kΩ) 511 ± 4