Moisture content of the PES/GL treatments before and after rinsing. Bath exhaustion of 100% GL owf at a 1/15 bath ratio at 100 °C, t = 60 min in neutral or alkaline conditions and with microwave irradiation (MW) of the GL solution at different concentrations, power and treatment times.

N Sample/Treatment Moisture at 65%RH (% owf) Moisture after Rinsing at 65%RH (% owf)
Non Treated PES (PES NT) 0.5 ± 0.1 -
11 PES 100% GL, BR 1/10, T 60 °C, 180 min 12.6 ± 0.2 1.2 ± 0.3
12 PES 100% GL, BR 1/15, T 100 °C, 60 min 10.1 ± 1.0 1.71 ± 0.3
13 PES 100% GL, BR 1/15 NaOH, T 100 °C, 60 min 13.5 ± 1.2 1.51 ± 0.5
14 PES 50%GL, BR 1/15 NaOH, RT, 2 min, 300 W (MW) 6.4 ± 0.9 0.84 ± 0.4
15 PES 50%GL, BR 1/15 NaOH, RT, 5 min, 500 W (MW) 8.8 ± 0.9 1.68 ± 0.3
16 PES 50% GL, BR 1/15 H2O, RT, 2 min, 300 W (MW) 4.6 ± 0.4 1.68 ± 0.2
17 PES 50% GL, BR 1/15 H2O, RT, 5 min, 500 W (MW) 7.6 ± 0.6 1.26 ± 0.7
18 PES 100% GL, BR 1/15 NaOH, RT, 2 min, 300 W (MW) 10.2 ± 0.6 2.19 ± 0.9
19 PES 100% GL, BR 1/15 NaOH, RT, 5 min, 500 W (MW) 13.0 ± 0.5 3.42 ± 0.5
20 PES 100% GL, BR 1/15 H2O, RT, 2 min, 300 W (MW) 11.8 ± 0.7 2.40 ± 0.1
21 PES 100% GL, BR 1/15 H2O, RT, 5 min, 500 W (MW) 12.4 ± 0.9 2.25 ± 0.9

N = Treatment number