Skip to main content
. 2021 Aug 30;14(17):4936. doi: 10.3390/ma14174936

Table 2.

Fluoride ion release (ppm/mg) from fissure sealants into deionized water. Descriptive data are presented as mean values + standard deviation (SD).

Time Arkona (ppm/mg) Helioseal (ppm/mg) Conseal (ppm/mg) Helioseal Plus (ppm/mg)
1 h 0.0005 ± 0.0002 0.0005 ± 0.0001 0.0041 ± 0.0014 0.0012 ± 0.0002
3 h 0.0006 ± 0.0002 0.0007 ± 0.0004 0.0019 ± 0.0007 0.0016 ± 0.0009
24 h 0.0007 ± 0.0001 0.0008 ± 0.0004 0.0017 ± 0.0002 0.0015 ± 0.0005
48 h 0.0013 ± 0.0004 0.0006 ± 0.0002 0.0016 ± 0.0003 0.0015 ± 0.0005
72 h 0.0009 ± 0.0002 0.0007 ± 0.0002 0.0012 ± 0.0003 0.0005 ± 0.0001
96 h 0.0005 ± 0.0001 0.0005 ± 0.0001 0.0007 ± 0.0002 0.0004 ± 0.0001
1 week 0.0007 ± 0.0002 0.0007 ± 0.0001 0.0009 ± 0.0001 0.0007 ± 0.0001
2 weeks 0.0010 ± 0.0005 0.0010 ± 0.0003 0.0012 ± 0.0005 0.0013 ± 0.0004
Mean value ± SD 0.0008 ± 0.0004 0.0007 ± 0.0003 0.0017 ± 0.0012 0.0011 ± 0.0006
p-value
(ANOVA for dependent samples)
0.0004 * 0.143 <0.0001 * 0.0001 *
p-value
(ANOVA for independent groups)
<0.0001 *
Tukey’s post-hoc test:
Arkona -
Helioseal 0.936 -
Conseal <0.0001 * <0.0001 * -
Helioseal Plus 0.190 0.049 * 0.0009 * -

* statistically significant.