Skip to main content
. 2021 Sep 6;13(17):3017. doi: 10.3390/polym13173017

Table 2.

Experimental fracture loads and fracture angle of the VO-notched specimens.

γ (°) ρ (mm) Specimen Type Fracture Load (N) Standard
Deviation
Fracture Location (°) Standard Deviation
F1 F2 F3 Faverage θ0,1 θ0,2 θ0,3 θ0,average
15° 2.5 CT 111 155 148 138 19.30 0 0 0 0 0
DCB1 67 59 51 59 6.53 74 63 72 70 4.78
DCB2 43 48 59 50 6.68 76 75 71 74 2.16
3.0 CT 155 154 147 152 3.55 0 0 0 0 0
DCB1 75 79 65 73 5.88 68 70 69 69 0.82
DCB2 52 49 43 48 3.74 73 76 69 73 2.87
30° 2.5 CT 144 124 110 126 13.59 0 0 0 0 0
DCB1 79 68 84 77 6.68 73 65 76 71 4.64
DCB2 45 53 46 48 3.55 76 71 71 73 2.36
3.0 CT 166 145 151 154 8.83 0 0 0 0 0
DCB1 79 86 84 83 2.94 65 69 64 66 2.16
DCB2 43 40 46 43 2.45 71 68 72 70 1.70