Skip to main content
. 2021 Sep 6;13(17):3017. doi: 10.3390/polym13173017

Table 6.

A comparison between the test results obtained from sharp V notched specimens (ρ = 0.0 mm) [17] and VO-notched specimens (ρ = 2.5 mm).

γ (°) ρ (mm) Specimen Type Fracture Load (N) Fracture Initiation Angle (°)
15 0.0 CT 90.3 0
DCB1 45 43
DCB2 30.5 46
2.5 CT 138 0
DCB1 59 70
DCB2 50 74
30 0.0 CT 67.3 0
DCB1 48.6 30
DCB2 30.6 35
2.5 CT 126 0
DCB1 77 71
DCB2 48 73