Summary of the exposure time (tET), over-voltage Vov, total charge QET (as defined by Equation (2)) and average current i(t) during SiPM spectral measurements.

Exposure Time tET FBK VUV-HD3 HPK VUV4
Visible NIR Visible NIR
Vov [V] 12.1 ± 1.0 12.1 ± 1.0 10.7 ± 1.0 10.7 ± 1.0
8 h 20 min i(t) [μA] 59.1 ± 1.2 66.2 ± 1.3 78.8 ± 0.6 33.3 ± 0.3
QET [C] 1.77 ± 0.12 1.99 ± 0.12 2.36 ± 0.12 1.00 ± 0.12
Vov [V] 12.4 ± 1.0 12.4 ± 1.0 10.8 ± 1.0 10.8 ± 1.0
4 h 45 min i(t) [μA] 87.1 ± 0.6 97.5 ± 1.0 46.4 ± 0.4 88.0 ± 0.6
QET [C] 1.49 ± 0.09 1.67 ± 0.09 0.80 ± 0.09 1.51 ± 0.09
Vov [V] 12.8 ± 1.0 12.8 ± 1.0 11 ± 1 11 ± 1
3 h 20 min i(t) [μA] 200.9 ± 1.7 165.5 ± 1.3 240.5 ± 1.3 187.8 ± 1.2
QET [C] 2.41 ± 0.08 1.99 ± 0.08 2.89 ± 0.08 2.25 ± 0.08