Table 1.
FW | λabsa (nm) | ε (M − 1 cm−1) | λem(nm) | Δv (cm−1) | ΦFb | τ (ns) | kr (107 s−1) | knr (107 s−1) | |
---|---|---|---|---|---|---|---|---|---|
o-DAPA | 192.22 | 432 | 5160 | 531 | 4320 | 0.26 | 6.44 | 4.0 | 12 |
m-DAPA | 192.22 | 350 | 7050 | - | - | - | - | - | - |
p-DAPA | 192.22 | 482 | 2890 | 618 | 4570 | 0.06 | 1.84 | 3.3 | 51 |
4 | 436.46 | 370 | 3410 | 471 | 5800 | 0.18 | 5.83 | 3.1 | 14 |
5 | 276.29 | 405 | 5810 | 502 | 4770 | 0.73 | 8.93 | 8.1 | 3.1 |
6 | 392.45 | 416 | 6670 | 518 | 4730 | 0.61 | 9.09 | 6.7 | 4.3 |
7 | 334.38 | 435 | 7210 | 543 | 4570 | 0.29 | 6.14 | 4.7 | 12 |
8 | 234.26 | 445 | 3990 | 556 | 4490 | 0.30 | 5.93 | 5.0 | 12 |
9 | 292.34 | 446 | 3660 | 566 | 4750 | 0.27 | 4.89 | 5.5 | 15 |
10 | 263.30 | 456 | 5070 | 581 | 4720 | 0.23 | 2.96 | 7.7 | 26 |
aThe longest absorption maximum wavelengths. bAbsolute fluorescence quantum yields determined by a calibrated integrating sphere system. All measurements are made for CHCl3 solution samples.