Skip to main content
. 2021 Aug 31;8:696391. doi: 10.3389/fsurg.2021.696391

Table 1.

Basic characteristics of all the RCTs included in this meta-analysis.

References Country Fracture type Sample (n, 3D/C) Gender
(M/F)
Follow-up (month, mean) Time from injury to operation (days, 3D/C) 3D fracture model Fixator (3D/C) Outcomes
Chen et al. (16) China Die-Punch fractures 55/52 65/42 13.075 3.19 ± 1.70/
3.15 ± 1.55
Fracture model: Using CT scan [Star PACS system (INFINITT, Seoul, South Korea)], 3D image was created in Mimics software v10.01 (Materialise, Leuven Belgium); 3D printer (3D ORTHO; Waston Med Inc., Changzhou, Jiangsu, China) Steel plates and screws, K-wires Operation time, intraoperative blood loss, number of fluoroscopies
Chen et al. (17) China AO type C fractures 23/25 31/17 13.0 3.3 ± 1.8/
3.7 ± 1.6
Fracture model: Using CT scan [Star PACS system (INFINITT, Seoul, South Korea)], 3D image was created in Mimics software (version 10.01; Materialise, Leuven, Belgium); 3D printer (3D ORTHO; Waston Med Inc., Changzhou, Jiangsu, China) Metal plates and screws, K-wire Operation time, intraoperative blood loss, number of fluoroscopies
Shuang et al. (18) China Intercondylar humeral fractures 6/7 10/3 10.6 NR Fracture model: Using CT scan (1 mm), 3D image was created in Mimics v.11.1 software (Materialise, Ann Arbour, MI); 3D printer (SRP400B, Huasen 3D Printing Research, Changzhou, China) Steel plate and screws, K-wire Operation time
Maini et al. (19) India Acetabulum fracture 10/11 18/3 10.6 ≤ 21 Fracture model: Using CT scan, 3D image was created in MIMICS 8.13 software (Materialise, Leuven, Belgium): 3D printing machine EOSINT P380 (EOS, Birmingham, UK) and patient-specific 3D real model was generated using rapid prototyping technology. 3.5 mm reconstruction stainless steel plate Operation time, intraoperative blood loss
Maini et al. (20) India Acetabulum fracture 12/13 23/2 NA ≤ 21 Fracture model: Using CT scan (1 mm), 3D image was created in Mimics software; 3D printer [rapid prototyping technology in poly-lactic acid (PLA)] Pre-contoured reconstruction plates Operation time
Kong et al. (21) China Intra-articular distal radius fractures 16/16 19/13 6.0 ≤ 7 Fracture model: Using CT scan (1 mm), 3D image was created in Mimisc18.0 (Materialise, Belgium) software; 3D printer K-wire, screws Operation time, intraoperative blood loss, number of fluoroscopies
Yang et al. (22) China Trimalleolar fracture 15/15 16/14 NA 5.4 (4–12) Model: Using CT scan (1 mm), 3D image was created in Mimics l0.01 software; 3D printer (FlashForge Ltd., ZhengJiang, China). Polylactic acid (PLA) was used as the printing material (FlashForge Ltd., 1.75 mm in diameter) The internal fixation plate Operation time, intraoperative blood loss
Yang et al. (23) China Elbow fractures 20/20 28/12 10.6 NR Model: Using CT scan (1 mm), 3D image was created in Mimics 10.01 software; 3D printer (FlashForge Ltd., ZhengJiang, China). PLA and ABS were used as the printing materials (FlashForge Ltd., 1.75 mm in diameter) Steel plates and screws Operation time, intraoperative blood loss
You et al. (24) China Complex proximal humeral fractures 34/32 39/27 22.3 NR Model: Using CT scan (1 mm, SIEMENS, Germany), 3D image was created in Mimics 16.0 (Materialise, Belgium); 3D printer [rapid prototyping equipment (3D System Project 660 Pro)] Steel plates and screws Operation time, intraoperative blood loss, number of fluoroscopies
Zheng et al. (25) China Humeral intercondylar fractures 43/48 49/42 15.5 4.3 ± 1.4
4.2 ± 1.1
Model: Using CT scan [Star PACS system (INFINITT, Seoul, South Korea)], 3D image was created in 3D image was created in Mimics software v15.0 (Materialise, Leuven, Belgium); 3D printer (3D ORTHO Waston Med Inc. Changzhou, Jiangsu, China) Steel plate and screws Operation time, intraoperative blood loss, number of fluoroscopies
Zheng et al. (26) China Calcaneal Fractures 35/40 44/31 14.8 7.69 ± 2.3/
7.60 ± 1.7
Model: Using CT scan, 3D image was created in 3D image was created in Mimics software v17.0 (Materialise, Leuven, Belgium); 3D printer (3D ORTHO Waston Med Inc. Changzhou, Jiangsu, China) Steel plate and screws Operation time, intraoperative blood loss, number of fluoroscopies
Zheng et al. (27) China Pilon fracture 45/48 66/27 20.2 7.6 ± 2.5/
8.1 ± 2.3
Model: Using CT scan (tar PACS system [INFINITT, Seoul, South Korea)], 3D image was created in Mimics software v17.0 (Materialise, Leuven, Belgium); 3D printer (3D ORTHO Waston Med, Inc., Changzhou, Jiangsu, China) Metal plates and screws Operation time, intraoperative blood loss, number of fluoroscopies