Skip to main content
. Author manuscript; available in PMC: 2022 Sep 1.
Published in final edited form as: Artif Intell Med. 2021 Aug 6;119:102136. doi: 10.1016/j.artmed.2021.102136

Table 5.

Results and the corresponding 95% CIs for the teacher model as percentages. The above results were obtained on the respective test sets, detailed in Sections 4.2, 4.3, and 4.4.

CD LUAD RCC
Accuracy 87.06 (85.65–88.48) 94.51 (92.77–96.20) 90.16 (87.62–92.57)
F1-Score 75.44 (72.31–78.51) 80.43 (70.86–88.17) 80.09 (74.02–85.64)
Precision 75.62 (72.55–78.66) 80.41 (70.55–89.56) 78.54 (72.75–84.13)
Recall 77.15 (74.19–80.06) 81.67 (71.20–90.43) 85.19 (80.07–89.70)